AMERICAS

PRODUCTS

Vibration Controller

K2

K2

Common hardware supports all types of vibration test.

The K2 controller provides the precision and repeatability required to test with condence during both product development and series production.
The K2 hardware and software has been developed in-house, giving IMV full design control of this important part of a vibration system.
The K2 system offers enhanced functions and operability based on the most advanced technologies and incorporating feedback from our customers.

Features

■User-friendly interface
  • Instinctive Operation

    [Instinctive Operation]

    Easily-recognised icons are used for file management.

  • Simplified definition

    [Short-cut operations]

    The key operations are initiated using a simplified set of commands.

  • Help

    [Help]

    Each stage of operation is supported by detailed help pages.

■Easy-to-use Functions
  • Web monitor

    [Web monitor]

    A user can monitor a vibration test remotely by connecting over the internet.

  • Report generator

    [Report generator]

    Results can be exported to Microsoft Word in a range of customised formats.

  • Report generator

    [Scheduler]

    Define the test schedule and execute it in order.

■Precision control capabilities
K2 employs high-resolution 24-bit A/D and D/A converters to achieve high-precision, repeatable control.
■Safety interlock function
A hardware mute function operating independently of software provides complete protection for the vibration system and payload.
■E-mail notification
Remote sites can be notified by email of any abnormality during testing or termination of a test.
■Data saving
Test definitions and results are output from the K2 in CSV format.

Software

Common optional software Outline
CAPTURE:
Analogue waveform
signal data program

Provides analogue waveform signal capture, saved data can then be used as the reference of SHOCK, BMAC waveform controls or Random vibration PSD control.

• Sampling Frequency 51.2 kHz maximum
• Data Length Maximum 5000 k points
• Input Channel Maximum 64
• Waveform edit/analysis function Filtering, Frequency transfer processing, PSD transfer,
Transmissibility ratio between channels
SCHEDULER:Test scheduler Pre-defined tests can be executed in sequence.

Specifications

Main Enclosure
Number of Slots 3 (Expandable by connecting additional slave units)
AC Power Single-phase AC, 100 V-240 V (Auto-selected)
Extension
Additional units can be interconnected (Providing support for large-scale systems)
External Communication Contact I/O (for Emergency stop)
Ambient Conditions 0-40 ℃, below 85 % RH, no condensation
Dimensions W 430×H 100×D 340mm (excluding connectors etc.)
Mass Approximately 6.0kg
8-channel Input Module (option)
Number of Channels
8
Input Connector
BNC
Input Signal
Charge,Voltage,IEPE
Charge Amplifier Sensitivity 1.0 mV/pC or 10 mV/pC
Charge Amplifier Cut-off 0.32 Hz
Maximum Input Charge Input ±10000 pC or ±1000 pC
Voltage Input ±10000 mV
IEPE Input ±10000 mV
Sampling Frequency 51.2 kHz maximum
Voltage Input Coupling AC or DC
AC Coupling Cut-off 0.1 Hz
CCLD Amplifier(IEPE) +24 VDC, 3.5 mA
TEDS(IEPE) Version 0.9, Version 1.0
A/D Converter Type : ΔΣ
Resolution : 24-bit
Dynamic range : 117 dB
Digital filter : Pass-band ripple ±0.001 dB
        : Stop-band attenuation 110 dB
4-Channel Input and 4-Channel Output Module (standard)
●Input Section
Number of Channels 4
Input Connector BNC
Input Signal
Charge, Voltage, IEPE
Charge Amplifier Sensitivity 1.0 mV/pC or 10 mV/pC
Charge Amplifier Cut-off 0.32 Hz
Maximum Input Charge Input ±10000 pC or ±1000 pC
Voltage Input ±10000 mV
IEPE Input ±10000 mV
Sampling Frequency 51.2 kHz maximum
Voltage Input Coupling
AC or DC
AC Coupling Cut-off 0.1 Hz
CCLD Amplifier(IEPE) +24 VDC, 3.5 mA
TEDS(IEPE) Version 0.9, Version 1.0
A/D Converter Type : ΔΣ
Resolution : 24-bit
Dynamic range : 117dB
Digital filter : Pass-band ripple ±0.001 dB
        : Stop-band attenuation 110 dB
●Output Section
Number of Channels
4 (One channel is reserved for drive output)
Output Connector BNC
Output Signal
Voltage
Maximum Output
±10000mV
Sampling Frequency
51.2kHz maximum
D/A Converter Type : ΔΣ
Resolution : 24-bit
Dynamic range : 120 dB
Digital filter : Pass-band ripple ±0.005 dB
        : Stop-band attenuation 75 dB

Minimum Specifcation of PC

  • ● One built-in PCI Express x1 slots
  • ● Memory required (for 8 input channels)
      Windows XP (32 bit):1 GB or more
      Windows 7 (32 bit):2 GB or more
      Windows 7 (64 bit):4 GB or more
      * The following conditions may require memory expansion
      • Where the number of input and output channels exceeds 8 channels
      • When using LONG WAVEFORM or the MEGA POINT option of Shock
      • Multi-freedom vibration control system
  • ● CD-ROM Drive (required for installation)
  • ● One USB port
  • ● Requires Microsoft Windows XP Professional SP3 (32 bit) or Windows 7 Professional (32 bit/64 bit)
K2 Sprint

K2 Sprint

Common hardware supports all types of vibration test.

While inheriting all of the performance and features of K2, K2 Sprint offers improved cost-effectiveness with 2-channel hardware.
K2 Sprint is best-suited to single monitor-channel operation.

[Differences from K2]
●Input 2 channels (No expansion)
●Output 2 channels (No expansion)

Features

■User-friendly interface
  • Instinctive Operation

    [Instinctive Operation]

    Easily-recognised icons are used for file management.

  • Simplified definition

    [Short-cut operations]

    The key operations are initiated using a simplified set of commands.

  • Help

    [Help]

    Each stage of operation is supported by detailed help pages.

■Easy-to-use Functions
  • Web monitor

    [Web monitor]

    A user can monitor a vibration test remotely by connecting over the internet.

  • Report generator

    [Report generator]

    Results can be exported to Microsoft Word in a range of customised formats.

  • Report generator

    [Scheduler]

    Define the test schedule and execute it in order.

■Precision control capabilities
K2 employs high-resolution 24-bit A/D and D/A converters to achieve high-precision, repeatable control.
■Safety interlock function
A hardware mute function operating independently of software provides complete protection for the vibration system and payload.
■E-mail notification
Remote sites can be notified by email of any abnormality during testing or termination of a test.
■Data saving
Test definitions and results are output from the K2 in CSV format.

Software

Common optional software Outline
CAPTURE:
Analogue waveform
signal data program

Provides analogue waveform signal capture, saved data can then be used as the reference of SHOCK, BMAC waveform controls or Random vibration PSD control.

• Sampling Frequency 51.2 kHz maximum
• Data Length Maximum 5000 k points
• Input Channel Maximum 64
• Waveform edit/analysis function Filtering, Frequency transfer processing, PSD transfer,
Transmissibility ratio between channels
SCHEDULER:Test scheduler Pre-defined tests can be executed in sequence.

Specifications

Main Enclosure
AC Power Single-phase AC, 100 V-240 V (Auto-selected)
External Communication Contact I/O (for Emergency stop)
Ambient Conditions 0-40 ℃, below 85 % RH, no condensation
Dimensions W 345 x H 40 x D 210 mm (Protruding part not induded)
Mass Approximately 6.0kg
●Input part
Number of Channels 2
Input Connector BNC
Input Signal
Charge, Voltage, IEPE
Charge Amplifier Sensitivity 1.0 mV/pC or 10 mV/pC
Charge Amplifier Cut-off 0.32Hz
Maximum Input Charge Input ±10000 pC or ±1000 pC
Voltage Input ±10000 mV
IEPE Input ±10000 mV
Sampling Frequency 51.2 kHz maximum
Voltage Input Coupling AC or DC
AC Coupling Cut-off 0.1Hz
CCLD Amplifier(IEPE) +24 VDC, 3.5 mA
TEDS(IEPE) Version0.9,Version1.0
A/D Converter Type : ΔΣ
Resolution : 24-bit
Dynamic Range: 117 dB
Digital Filter : Pass-band ripple ±0.001 dB
        : Stop-band attenuation 110 dB
●Output part
Number of Channels 2 (a channel is occupied for drive output)
Output Terminal BNC
Output Signal
Voltage
Maximum Output
±10000 mV
Sampling Frequency
51.2 kHz maximum
D/A Converter Type : ΔΣ
Resolution : 24-bit
Dynamic Range: 120 dB
Digital Filter : Pass-band ripple ±0.005 dB
        : Stop-band attenuation 75 dB

Minimum Specifcation of PC

  • ● One built-in PCI Express x1 slots
  • ● Memory required (for 8 input channels)
      Windows XP (32 bit):1 GB or more
      Windows 7 (32 bit):2 GB or more
      Windows 7 (64 bit):4 GB or more
      * The following conditions may require memory expansion
      • Where the number of input and output channels exceeds 8 channels
      • When using LONG WAVEFORM or the MEGA POINT option of Shock
      • Multi-freedom vibration control system
  • ● CD-ROM Drive (required for installation)
  • ● One USB port
  • ● Requires Microsoft Windows XP Professional SP3 (32 bit) or Windows 7 Professional (32 bit/64 bit)